We have compiled a list of manufacturers, distributors, product information, reference prices, and rankings for Chromatography equipment.
ipros is IPROS GMS IPROS One of the largest technical database sites in Japan that collects information on.

Chromatography equipment Product List and Ranking from 15 Manufacturers, Suppliers and Companies

Last Updated: Aggregation Period:Jan 07, 2026~Feb 03, 2026
This ranking is based on the number of page views on our site.

Chromatography equipment Manufacturer, Suppliers and Company Rankings

Last Updated: Aggregation Period:Jan 07, 2026~Feb 03, 2026
This ranking is based on the number of page views on our site.

  1. 東ソー バイオサイエンス事業部 計測分野 Tokyo//Chemical
  2. サーモフィッシャーサイエンティフィック株式会社/Thermo Fisher Scientific K.K. Tokyo//Testing, Analysis and Measurement
  3. 同仁グローカル Kumamoto//others
  4. 4 アジレント・テクノロジー株式会社 Tokyo//Testing, Analysis and Measurement
  5. 5 TECHNICAL INFOMATION INSTITUTE CO.,LTD Tokyo//Service Industry

Chromatography equipment Product ranking

Last Updated: Aggregation Period:Jan 07, 2026~Feb 03, 2026
This ranking is based on the number of page views on our site.

  1. Lipid fractionation: Fatty acid analysis by type of lipid (TLC) 同仁グローカル
  2. Technical Data: SEC (GPC/GFC) Data Collection 東ソー バイオサイエンス事業部 計測分野
  3. GPC 総合カタログ 東ソー バイオサイエンス事業部 計測分野
  4. 4 High-speed GPC device 'HLC-8420GPC' 東ソー バイオサイエンス事業部 計測分野
  5. 5 [Seminar Materials Released] Basics of Ion Chromatography サーモフィッシャーサイエンティフィック株式会社/Thermo Fisher Scientific K.K.

Chromatography equipment Product List

1~30 item / All 54 items

Displayed results

[Seminar Materials Released] Basics of Ion Chromatography

Recommended for those who will be involved in ion chromatography and those who want to relearn the basics!

We are pleased to announce the release of the slide materials from the seminar program "Basics of Ion Chromatography," which was popular at the Dionex IC Technology Seminar 2019 - Basic Course on Chromatography! This seminar focuses on understanding and acquiring essential foundational knowledge related to analysis, such as the principles and theories of ion exchange separation and the basic components of the equipment, making it suitable for beginners in ion chromatography.

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Basics of Ion Chromatography: The Flow Rate of the Eluent Affecting Separation

A clear explanation of the basics of ion chromatography! Let's understand how changes in the flow rate of the eluent affect separation.

Ion exchange separation occurs due to the competition between the measurement ions and the eluent ions on the ion exchange sites. One of the factors that affects this ion exchange separation is the change in the flow rate of the eluent. I will explain the differences in the chromatograms obtained by varying the flow rate of the eluent and the points to be cautious about.

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Basics of Ion Chromatography: Temperature Affecting Separation

A clear explanation of the basics of ion chromatography! Let's understand the impact of changes in column temperature on separation.

Ion exchange separation occurs due to the competition between the measurement ions and the eluent ions on the ion exchange sites. One of the factors that affects this ion exchange separation is the change in column temperature. When the column temperature is altered, the retention time of the measurement ions changes due to variations in separation equilibrium, diffusion rates, degree of dissociation, and the viscosity of the eluent. The impact of temperature varies depending on the type of measurement ions and also changes with different columns and eluents. This factor of temperature will be explained.

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

[Analysis Case] Risk Assessment of Nitrosamines in Pharmaceuticals

[Introduction to Ion Chromatography Cases] Measurement of Nitrite and Amines

N-nitrosodimethylamine (NDMA) is an organic compound represented by the chemical formula (CH3)2NNO. NDMA is a known carcinogen found in some fermented foods. The measurement of nitrite ions can be performed using wet chemical analysis, but a representative method in instrumental analysis is ion chromatography (IC). In IC, separation is achieved using an ion exchange column, and detection is carried out using conductivity detection, electrochemical detection, UV detection, or mass spectrometry. Methods using IC typically require little to no sample pretreatment for many pharmaceutical samples, and derivatization of the target components is also unnecessary.

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

[Case Study] Analysis of Tocopherols α, β, γ, and δ using 2D-LC

Vitamin E (alpha, beta, gamma, delta tocopherols) in vegetable oils can be separated and quantified without the influence of interfering components using single-loop heart-cut 2D-LC.

This document introduces a method for the high-precision separation and quantification of four types of tocopherols contained in vegetable oils using the single-loop heart-cut 2D-LC method. Under the separation conditions of a reverse-phase system using a general ODS column, the separation of β-tocopherol and γ-tocopherol is difficult; however, the 2D-LC method allows for easy separation. In the first dimension, tocopherols and interfering components in the sample are separated, and in the second dimension, the four types of tocopherols (α, β, γ, δ) are separated. The repeatability of the standard samples achieved a high reproducibility with RSD < 0.1%. Additionally, measurements conducted on multiple vegetable oils showed that quantification was possible without the influence of interfering peaks. The single-loop heart-cut 2D-LC method is the simplest technique among 2D-LC methods, making it applicable for routine analysis and a useful tool for food analysis involving samples with a high content of matrix components. 【Features】 ■ High-precision separation achieved with the single-loop heart-cut 2D-LC method ■ Separation of β-tocopherol and γ-tocopherol, which is difficult in reverse-phase systems ■ Effective separation of interfering substances in food ■ High reproducibility with repeatability of RSD < 0.1%

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Band concentration effect by GC×GC modulator

This is a special report on the band concentration effect using a GC×GC modulator.

At LECO Japan, we will pick up samples that are expected to enhance the precision, efficiency, and safety of your analytical operations using LECO's analytical instruments, and present them as a special report. Please take a look. If you would like to know whether similar samples can be applied, please feel free to contact us.

  • Other measurement, recording and measuring instruments
  • Analytical Equipment and Devices
  • Chromatography equipment

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

GCxGC

Improved peak capacity and detection ability! It is possible to identify three times the number of compounds.

GCxGC is a powerful analytical method that utilizes two columns with different phase selections connected by a modulator. Also known as comprehensive two-dimensional gas chromatography, it enhances peak capacity, resolution, and detection capability depending on the setup. On average, GCxGC analysis has five times the sensitivity of conventional GC-MS analysis and can identify three times the number of compounds. 【Features】 <Simply GCxGC> ■ Guides you through the steps to create a GCxGC analytical method optimized for complex samples ■ Develops a GCxGC method from scratch ■ Converts existing 1D methods to GCxGC ■ Measures secondary oven offset and secondary column length ■ Streamlines the method development cycle by omitting unnecessary tests *For more details, please refer to the related links or feel free to contact us.

  • Analytical Equipment and Devices
  • Chromatography equipment

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

[Book] Trends in PFAS Regulation and Response Technologies (No. 2255)

Available for preview - Analysis, removal, decomposition, development of alternative materials -

★ Latest regulatory status in Europe, the United States, China, and Japan! Required responses for manufacturing, use, and import/export operations! ★ Development examples of alternative materials with performance comparable to fluorinated coatings, additives, and polymer materials! --------------------- ■ Key points of this document 1. Screening, quantification, and structural analysis of PFAS - Usage of reagents, instruments, and certified standard materials for analysis - Types of columns, selection methods, and sample injection techniques - Sample pretreatment in analysis and points for reducing blanks - Guidelines for PFAS analysis in industrial products, tap water, and food, as well as sample preparation and measurement conditions - Data analysis of chromatography and validity testing of results 2. Adsorption, removal, and degradation of PFAS - Removal of PFAS using activated carbon, zeolites, magnesium, and MOFs - Treatment of PFAS-contaminated water using ion exchange resins and separation membranes - Deactivation of PFAS through hydrolysis, electrolysis, thermal decomposition, and incineration - Decomposition of PFAS using subcritical water treatment, atmospheric pressure plasma, cavitation, and bacteria - Insolubilization treatment of PFAS-contaminated soil and in-situ purification

  • IPROS3391385136135994447_220x220.png
  • others
  • Chromatography equipment

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Technical Data: Bioseparation Handbook

A comprehensive explanation of various separation modes, their principles, characteristics, and more, covering a wide range from the basics to actual measurements.

This document is a technical material that explains liquid chromatography. Liquid chromatography has become an essential method for the separation and analysis of biological samples. This guide provides a comprehensive explanation of various separation modes of liquid chromatography, their principles, and features, ranging from the basics to actual measurements. [Contents (excerpt)] - Properties of proteins and nucleic acids - Separation methods for biopolymers - Liquid chromatographs used for measuring biopolymers - Size exclusion chromatography - Ion exchange chromatography *For more details, please refer to the PDF document or feel free to contact us.

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Technical Data: SEC (GPC/GFC) Data Collection

Publishing SEC (GPC/GFC) data of various synthetic polymers! Introducing GPC data for 112 actual samples!

This document is a collection of data on size exclusion chromatography (SEC, GPC, GFC). (The SEC of biomacromolecules such as proteins is explained in detail in the "Bioseparation Handbook.") 【Contents】 Types and characteristics of columns Solvents used in SEC and their properties *Data examples* Polyolefins, PPS Synthetic rubber Styrene-based resins Polyvinyl chloride and vinyl chloride copolymers Polycarbonate Polyvinyl acetate, polyvinyl alcohol Methacrylic resins Polyamides Polyethers Polyesters Phenolic resins Urea resins, melamine resins, cresol resins Epoxy resins Polyurethanes Fluorine-based resins Cellulose derivatives and cellulose Organosiloxane-based polymers Cyanoacrylate resins Polysulfone, polyethersulfone Polyimide Polylactic acid, polycaprolactone Water-soluble polymers and polysaccharides *For more details, please refer to the PDF document or feel free to contact us.*

  • Analytical Equipment and Devices
  • Chromatography equipment

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

GPC 総合カタログ

信頼と安心の創出!SuperHZシリーズやSuperMultiporePWシリーズなどをご紹介

当カタログでは、様々な「GPC」をご紹介しております。 優れた安定性と再現性を実現した、高速GPC装置「HLC-8420GPC EcoSEC Elite」をはじめ、優れた操作性のGPCワークステーション「EcoSEC Elite-WS」、超高温領域でも高い安定性を実現する、高温GPC装置 「HLC-8321GPC/HT」などを豊富に掲載。 画像と共に掲載しており、導入検討の際に参考にしやすい一冊と なっております。ぜひ、ご一読ください。 【掲載内容(一部)】 ■高速GPC装置 HLC-8420GPC EcoSEC Elite ■GPCワークステーション EcoSEC Elite-WS ■高温GPC装置 HLC-8321GPC/HT ■GPCワークステーション 8321GPC-WS ■SECカラム ※詳しくはPDF資料をご覧いただくか、お気軽にお問い合わせ下さい。

  • Other physicochemical equipment
  • Chromatography equipment

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Scalable purification of full capsid AAV by chromatography.

Introducing a scalable AAV purification process and a method for separating full capsids and empty capsids using anion exchange chromatography.

Adeno-associated virus (AAV) is widely used as a vector for gene therapy. While it is often purified using ultracentrifugation at the lab scale, this method becomes difficult to scale up. A scalable method for purification is chromatography; however, separating full capsids (hereafter referred to as "full") that contain the genome from empty capsids (hereafter referred to as "empty") that do not contain the genome and do not contribute to titer has been challenging. When using AAV as a vector for gene therapy, it is desirable to remove empty capsids as much as possible due to their impact on titer and issues related to immunogenicity. This application note introduces a scalable AAV purification process and presents a method for separating empty and full capsids using anion exchange chromatography across multiple serotypes.

  • others
  • Chromatography equipment

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Equipped with PIC-80 (dual channel) auto sampler.

The warranty period is 5 years! We will introduce various components such as high-pressure transfer pumps, anion columns, and cation columns.

■Column Temperature Box and Constant Temperature Device ・With official patent certificate ■Thermal Conductivity Detector ・5-electrode conductivity cell ■High-Pressure Transfer Pump ・Pressure test: 42Mpa ■6-Port Sampling Valve ・Texture: Peak ■Flow Path Device ・Texture: Peak ■Anion Column ・Test items: F-, Cl-, NO2-, PO4^3-, Br-, SO4^2-, NO3-, ClO2-, BrO3-, ClO3- ■Anion Suppressor ・Automatic regeneration ■Cation Column ・Test items: Li+, Na+, NH4+, K+, Ca2+, Mg2+, Sr2+, Ba2+ ■Cation Suppressor ・Automatic regeneration ■IC Workstation ・Software ■Tools and Enclosures ・Spare parts and toolbox ■Auto Sampler ・Model PAS-III-DL-100, 100 units *For more details, please refer to the PDF document or feel free to contact us.*

  • Analytical Equipment and Devices
  • Chromatography equipment

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

ACQUITY APC System

Next-generation GPC that achieves faster analysis while maintaining separation capability.

Japan Waters Corporation offers a next-generation ACQUITY APC system for polymer separation that enables extremely high-resolution size-based separations very quickly in the characterization analysis of polymers and oligomers using chromatography. 〇Features - Enables analysis that is 5 to 20 times faster than conventional GPC/SEC analysis conditions. - High resolution increases calibration points in the low molecular weight region, allowing for higher precision data acquisition from higher quality calibration curves. *For more details, please download the PDF or feel free to contact us.

  • Analytical Equipment and Devices
  • Chromatography equipment

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Chemical Soft Development Research Institute Co., Ltd. Achievement Introduction

Introducing a variety of achievements such as acrylation, chlorination (chlorination), and glycosylation!

We will introduce examples of chemical reactions we have successfully conducted and possible purification methods. In chemical reactions, we have a wide variety of achievements, including "sulfinylation," "contact hydrogenation," and "transmetalation." Additionally, purification can be performed using column chromatography, thin-layer chromatography (normal phase), and distillation. [Examples of Successful Chemical Reactions (Excerpt)] ■Acrylation ■Azidation ■Acylation ■Acetalization ■Acetylation ■Amidation *For more details, please refer to the PDF document or feel free to contact us.

  • Chemicals
  • Chromatography equipment

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Hydrophilic interaction chromatography

It is possible to strongly retain solutes! Beneficial not only for LC/MS but also for preparative chromatography.

This document explains Hydrophilic Interaction Liquid Chromatography (HILIC), which is a suitable separation method for highly polar hydrophilic compounds. It includes the basic theory of HILIC and notes on precautions when using the separation mode. Additionally, it introduces the zwitterionic ZIC-HILIC series from Merck SeQuant and describes application examples for various hydrophilic compounds. We encourage you to read it. [Contents (excerpt)] ■ Introduction ■ For first-time users of ZIC-HILIC ■ Why HILIC mode? ■ Equipment ■ Principle of separation *For more details, please refer to the PDF document or feel free to contact us.

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Basics of Ion Chromatography: Hydrophobicity Affecting Separation

A clear explanation of the basics of ion chromatography! Let's understand the impact of hydrophobic interactions on separation.

Ion exchange separation occurs due to the competition between the measured ions and the eluent ions on the ion exchange sites. One factor that affects this ion exchange separation is hydrophobic interaction. I will explain this factor of hydrophobicity.

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Basics of Ion Chromatography: The Concentration and Types of Eluents Affecting Separation

A clear explanation of the basics of ion chromatography! Let's understand the concentration and types of elution solutions.

Ion exchange separation occurs due to the competition between the measurement ions and the eluent ions on the ion exchange sites. This explains the concentration and types of eluent that affect this ion exchange separation.

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Basics of Ion Chromatography: Principles of Ion Exchange Separation

A clear explanation of the basics of ion chromatography! Let's understand ion exchange separation.

Ion exchange separation is the fundamental mechanism of separation in ion chromatography, where ionic components repeatedly adsorb and desorb between the ion exchange sites and the electrolyte solution. This principle and its characteristics will be explained.

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Transfer of the analysis method for chlorhexidine impurities.

We will explain the key points for successfully transferring HPLC analysis methods using the results of rigorous analytical comparisons!

Transferring liquid chromatography (LC) methods between instruments is a challenging task that many analytical laboratories frequently face. The success of this method transfer depends on many factors, making it important to reduce the differences between the systems being transferred and the robustness of the method being transferred. This application note presents a smooth transfer from the Thermo Scientific UltiMate 3000 HPLC system to the Thermo Scientific Vanquish Core HPLC system using an HPLC method from the European Pharmacopoeia.

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

[Case Study] Simultaneous Analysis of Vitamins A, D, and E using 2D-LC

Simplifying the preprocessing with the single loop heart cut 2D-LC method significantly reduces analysis time. It enables the highly sensitive detection of vitamins A, D, E, and their isomers.

This technical document introduces a rapid and quantitative analytical method for the simultaneous detection of seven types of vitamins (vitamin A, vitamin D2, vitamin D3, and four types of vitamin E isomers) in infant formula using a conventional HPLC system with a diode array detector and a fluorescence detector, following offline solid-phase extraction (SPE) and two-dimensional liquid chromatography (2D-LC) analysis. By changing the traditional liquid-liquid extraction method to solid-phase extraction, the time required for sample preparation was reduced from 3 hours to 1 hour. Additionally, by simplifying the sample preparation and optimizing the separation conditions, the influence of the matrix was reduced, allowing for the detection of target substances with higher sensitivity. ■ Simplified sample preparation through two-dimensional liquid chromatography (2D-LC) analysis ■ Simultaneous separation analysis of vitamins A, D, E, and their isomers ■ Developed a method with higher recovery rates and sensitivity than liquid-liquid extraction ■ Simplified the preprocessing process and reduced analysis time by 2.5 times ■ Reduced the influence of the matrix and provided reliable data

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

High-Temperature GPC System 'HLC-8321GPC/HT'

High precision and excellent operability! A dedicated high-temperature GPC device capable of measuring various polymers.

The "HLC-8321GPC/HT" is a high-temperature GPC dedicated device capable of measuring various polymers such as polyolefins and PPS. By combining this high-temperature GPC dedicated device, which takes practicality, safety, and the environment into consideration, with a multi-station (GPC Workstation 8321GPC-WS) that allows for diverse data analysis, high-precision measurements can be achieved. The maximum temperature for temperature control is 220 °C, making it suitable for samples with high dissolution temperatures, including polyethylene and polypropylene, as well as PPS. 【Features】 ■ Covers ultra-high temperatures (up to 220 ºC) ■ Stable baseline ■ Fast startup ■ Comprehensive safety mechanisms ■ Excellent operability *For more details, please feel free to contact us.

  • Other physicochemical equipment
  • Other measurement, recording and measuring instruments
  • Chromatography equipment

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Bio-SEC LC specialized in the analysis of protein-based biopharmaceuticals.

An advanced light scattering detector enables accurate measurement of molecular weight and molecular size of molecules in solution for biochemical analysis.

Achieve excellent reproducibility and high-precision analysis! '1260 Infinity II Bio-SEC Multi-Detector System' Size exclusion chromatography (SEC) is a standard analytical method for measuring and quantifying monomers, dimers, aggregates, and potential degradation products, and is one of the common methods required for regulatory approval. With advanced light scattering detectors, accurate measurement of molecular weight and molecular size of molecules in solution is made possible, while simultaneously achieving higher sensitivity in the detection of aggregates in the analysis of biomacromolecules. 【Features】 ■ Measure molecular weight and molecular size with accuracy and high reproducibility ■ High-sensitivity detection of aggregates with a low dead volume light scattering detector ■ Accurate measurement of molecular size and molecular weight through advanced detection ■ Reduced need for data verification and re-analysis due to excellent reproducibility ■ Metal-free flow path achieves low surface activity and high salt concentration resistance *For more details, please refer to the PDF document or feel free to contact us.*

  • Analytical Equipment and Devices
  • Separation device
  • Chromatography equipment

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Composed of biocompatible materials: Universal binary UHPLC

Used in biopharmaceuticals (such as critical quality attributes) and other applications utilizing high salt concentration and high pH conditions.

The "1290 Infinity II Bio LC System" is a universal binary UHPLC composed of biocompatible materials. It is bio-compatible and ensures the integrity of biomolecules and the robustness of the system. Based on the proven 1290 Infinity II LC technology, method transfer can be easily implemented. Transferring from conventional equipment is also simple, saving time and effort in training, and it exhibits very high separation capability and resolution at pressures of up to 130 MPa, minimizing dispersion. 【Features】 ■ Ensures the integrity of biomolecules while minimizing unwanted surface interactions ■ Maximizes chromatographic resolution and minimizes dispersion ■ Improved flexibility and robustness, increasing equipment uptime ■ Saves effort in training ■ Can accommodate up to 6,144 samples, achieving excellent sample capacity *For more details, please refer to the PDF document or feel free to contact us.

  • Analytical Equipment and Devices
  • Separation device
  • Chromatography equipment

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Understand in 3 minutes! What is the configuration of HPLC equipment? Free explanatory materials available.

What is the configuration of HPLC (High-Performance Liquid Chromatography) equipment? A thorough and easy-to-understand explanation of the basics of HPLC! Free basic knowledge materials available!

High performance liquid chromatography (HPLC) is a type of liquid chromatography that achieves high separation efficiency by pressurizing the mobile phase liquid and using high-performance columns. It is utilized in various fields of chemical analysis. The HPLC system consists of a pump that delivers the mobile phase, an injector for sample injection, a column that separates the components in the sample, a column thermostat that maintains a constant column temperature, and a detector that identifies the separated components. This document provides a clear summary of the fundamentals of liquid chromatography (LC) separation, detectors, and principles. It is a valuable resource for those who are learning HPLC for the first time, those who wish to review from the basics, and those looking for educational materials for in-house training. [Contents (partial)] ■ Introduction ■ HPLC Equipment ■ Separation in HPLC ■ Detection *For more details, please download the PDF or feel free to contact us.

  • Analytical Equipment and Devices
  • Chromatography equipment

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

[Data] Measurement of resin molecular weight by high-temperature GPC (SEC)

The analysis device also supports the analysis and evaluation of polymers! Information on the configuration and principles of high-temperature SEC equipment is provided!

The molecular weight of resins such as plastics is not a single value but is composed of multiple molecular weights. By understanding this molecular weight and its distribution, it leads to a better understanding of the characteristics and degradation mechanisms of the resin. In this document, we will introduce a case study where we measured polypropylene resin (PP) samples with and without ultraviolet (UV) irradiation using a high-temperature GPC device suitable for measuring polyolefin-based materials that are difficult to dissolve in solvents at room temperature, and conducted data analysis. We encourage you to read it. [Contents] ■ Configuration and principles of high-temperature SEC ■ Analysis case: Molecular weight measurement of PP subjected to UV irradiation ■ Application examples ■ Specifications and considerations for high-temperature SEC *For more details, please refer to the PDF document or feel free to contact us.

  • Contract measurement
  • Contract Analysis
  • Other analyses
  • Chromatography equipment

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Thin-layer chromatography

Rapidness of gas chromatography, reliability of paper chromatography. Enables extensive analysis!

The HCG-100 model is for plate sizes of 200×200mm, 200×50mm, and 200×100mm. The HCG-80 model is for plate sizes of 100×100mm and 100×25mm. For details on thin-layer chromatography, please refer to "Download the catalog."

  • Other physicochemical equipment
  • Separation device
  • Chromatography equipment

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

High-Temperature GPC Device 'HLC-8321GPC/HT'

Achieving high stability even in ultra-high temperature environments! Demonstrating power in the analysis of high-temperature soluble samples.

The "HLC-8321GPC/HT" is a high-temperature GPC dedicated device designed with a basic concept prioritizing practicality, considering stability, high sensitivity, and fast startup, while also taking into account environmental and safety aspects. It demonstrates its power in analyzing high-temperature soluble samples that are difficult to measure with general-purpose GPC devices. Measurements can be conducted from 40°C in the ambient temperature range to ultra-high temperatures of 220°C. It is compatible with samples that have high dissolution temperatures, including polyethylene, polypropylene, and PPS. 【Features】 ■ Covers ultra-high temperatures (up to 220°C) ■ Stable baseline ■ Fast startup ■ Comprehensive safety mechanisms ■ Excellent operability ■ Compliant with FDA 21 CFR Part 11 *For more details, please refer to the PDF document or feel free to contact us.

  • Analytical Equipment and Devices
  • Chromatography equipment

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

High-speed GPC device 'HLC-8420GPC'

A new generation SEC system that achieves excellent stability and reproducibility.

The "HLC-8420GPC" is an integrated high-speed GPC device equipped with the necessary functional equipment for accurate molecular weight distribution measurement. Each unit, including the delivery pump, degassing section, and column oven, has been completely revamped to achieve excellent stability and reproducibility. By using options such as a solvent stocker and temperature-controlled sampler table unit, it can further enhance baseline stability and accommodate measurements of samples over time. 【Features】 ■ High stability and reproducibility ■ Fast startup ■ High speed, high separation, and solvent-saving ■ Excellent operability ■ Compliance with data integrity, including FDA 21CFR Part 11 *For more details, please refer to the PDF materials or feel free to contact us.

  • Analytical Equipment and Devices
  • Chromatography equipment

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Related Categories of Chromatography equipment