We have compiled a list of manufacturers, distributors, product information, reference prices, and rankings for Chromatography equipment.
ipros is IPROS GMS IPROS One of the largest technical database sites in Japan that collects information on.

Chromatography equipment Product List and Ranking from 15 Manufacturers, Suppliers and Companies

Last Updated: Aggregation Period:Oct 08, 2025~Nov 04, 2025
This ranking is based on the number of page views on our site.

Chromatography equipment Manufacturer, Suppliers and Company Rankings

Last Updated: Aggregation Period:Oct 08, 2025~Nov 04, 2025
This ranking is based on the number of page views on our site.

  1. 東ソー バイオサイエンス事業部 計測分野 Tokyo//Chemical
  2. サーモフィッシャーサイエンティフィック株式会社/Thermo Fisher Scientific K.K. Tokyo//Testing, Analysis and Measurement
  3. アジレント・テクノロジー株式会社 Tokyo//Testing, Analysis and Measurement
  4. 4 同仁グローカル Kumamoto//others
  5. 5 Sartorius Stedim Japan K.K. Tokyo//Pharmaceuticals and Biotechnology

Chromatography equipment Product ranking

Last Updated: Aggregation Period:Oct 08, 2025~Nov 04, 2025
This ranking is based on the number of page views on our site.

  1. High-speed GPC device 'HLC-8420GPC' 東ソー バイオサイエンス事業部 計測分野
  2. [Seminar Materials Released] Basics of Ion Chromatography サーモフィッシャーサイエンティフィック株式会社/Thermo Fisher Scientific K.K.
  3. GPC 総合カタログ 東ソー バイオサイエンス事業部 計測分野
  4. 4 Lipid fractionation: Fatty acid analysis by type of lipid (TLC) 同仁グローカル
  5. 5 Technical Data: High-Throughput Analysis of Halogens Using Combustion IC 東ソー バイオサイエンス事業部 計測分野

Chromatography equipment Product List

1~15 item / All 51 items

Displayed results

[Seminar Materials Released] Basics of Ion Chromatography

Recommended for those who will be involved in ion chromatography and those who want to relearn the basics!

We are pleased to announce the release of the slide materials from the seminar program "Basics of Ion Chromatography," which was popular at the Dionex IC Technology Seminar 2019 - Basic Course on Chromatography! This seminar focuses on understanding and acquiring essential foundational knowledge related to analysis, such as the principles and theories of ion exchange separation and the basic components of the equipment, making it suitable for beginners in ion chromatography.

  • Analytical Equipment and Devices

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Basics of Ion Chromatography: The Flow Rate of the Eluent Affecting Separation

A clear explanation of the basics of ion chromatography! Let's understand how changes in the flow rate of the eluent affect separation.

Ion exchange separation occurs due to the competition between the measurement ions and the eluent ions on the ion exchange sites. One of the factors that affects this ion exchange separation is the change in the flow rate of the eluent. I will explain the differences in the chromatograms obtained by varying the flow rate of the eluent and the points to be cautious about.

  • Analytical Equipment and Devices

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Basics of Ion Chromatography: Temperature Affecting Separation

A clear explanation of the basics of ion chromatography! Let's understand the impact of changes in column temperature on separation.

Ion exchange separation occurs due to the competition between the measurement ions and the eluent ions on the ion exchange sites. One of the factors that affects this ion exchange separation is the change in column temperature. When the column temperature is altered, the retention time of the measurement ions changes due to variations in separation equilibrium, diffusion rates, degree of dissociation, and the viscosity of the eluent. The impact of temperature varies depending on the type of measurement ions and also changes with different columns and eluents. This factor of temperature will be explained.

  • Analytical Equipment and Devices

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

[Analysis Case] Risk Assessment of Nitrosamines in Pharmaceuticals

[Introduction to Ion Chromatography Cases] Measurement of Nitrite and Amines

N-nitrosodimethylamine (NDMA) is an organic compound represented by the chemical formula (CH3)2NNO. NDMA is a known carcinogen found in some fermented foods. The measurement of nitrite ions can be performed using wet chemical analysis, but a representative method in instrumental analysis is ion chromatography (IC). In IC, separation is achieved using an ion exchange column, and detection is carried out using conductivity detection, electrochemical detection, UV detection, or mass spectrometry. Methods using IC typically require little to no sample pretreatment for many pharmaceutical samples, and derivatization of the target components is also unnecessary.

  • Other inspection equipment and devices

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

[Case Study] Analysis of Tocopherols α, β, γ, and δ using 2D-LC

Vitamin E (alpha, beta, gamma, delta tocopherols) in vegetable oils can be separated and quantified without the influence of interfering components using single-loop heart-cut 2D-LC.

This document introduces a method for the high-precision separation and quantification of four types of tocopherols contained in vegetable oils using the single-loop heart-cut 2D-LC method. Under the separation conditions of a reverse-phase system using a general ODS column, the separation of β-tocopherol and γ-tocopherol is difficult; however, the 2D-LC method allows for easy separation. In the first dimension, tocopherols and interfering components in the sample are separated, and in the second dimension, the four types of tocopherols (α, β, γ, δ) are separated. The repeatability of the standard samples achieved a high reproducibility with RSD < 0.1%. Additionally, measurements conducted on multiple vegetable oils showed that quantification was possible without the influence of interfering peaks. The single-loop heart-cut 2D-LC method is the simplest technique among 2D-LC methods, making it applicable for routine analysis and a useful tool for food analysis involving samples with a high content of matrix components. 【Features】 ■ High-precision separation achieved with the single-loop heart-cut 2D-LC method ■ Separation of β-tocopherol and γ-tocopherol, which is difficult in reverse-phase systems ■ Effective separation of interfering substances in food ■ High reproducibility with repeatability of RSD < 0.1%

  • Analytical Equipment and Devices

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Band concentration effect by GC×GC modulator

This is a special report on the band concentration effect using a GC×GC modulator.

At LECO Japan, we will pick up samples that are expected to enhance the precision, efficiency, and safety of your analytical operations using LECO's analytical instruments, and present them as a special report. Please take a look. If you would like to know whether similar samples can be applied, please feel free to contact us.

  • Other measurement, recording and measuring instruments
  • Analytical Equipment and Devices

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

GCxGC

Improved peak capacity and detection ability! It is possible to identify three times the number of compounds.

GCxGC is a powerful analytical method that utilizes two columns with different phase selections connected by a modulator. Also known as comprehensive two-dimensional gas chromatography, it enhances peak capacity, resolution, and detection capability depending on the setup. On average, GCxGC analysis has five times the sensitivity of conventional GC-MS analysis and can identify three times the number of compounds. 【Features】 <Simply GCxGC> ■ Guides you through the steps to create a GCxGC analytical method optimized for complex samples ■ Develops a GCxGC method from scratch ■ Converts existing 1D methods to GCxGC ■ Measures secondary oven offset and secondary column length ■ Streamlines the method development cycle by omitting unnecessary tests *For more details, please refer to the related links or feel free to contact us.

  • Analytical Equipment and Devices

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

[Book] Trends in PFAS Regulation and Response Technologies (No. 2255)

Available for preview - Analysis, removal, decomposition, development of alternative materials -

★ Latest regulatory status in Europe, the United States, China, and Japan! Required responses for manufacturing, use, and import/export operations! ★ Development examples of alternative materials with performance comparable to fluorinated coatings, additives, and polymer materials! --------------------- ■ Key points of this document 1. Screening, quantification, and structural analysis of PFAS - Usage of reagents, instruments, and certified standard materials for analysis - Types of columns, selection methods, and sample injection techniques - Sample pretreatment in analysis and points for reducing blanks - Guidelines for PFAS analysis in industrial products, tap water, and food, as well as sample preparation and measurement conditions - Data analysis of chromatography and validity testing of results 2. Adsorption, removal, and degradation of PFAS - Removal of PFAS using activated carbon, zeolites, magnesium, and MOFs - Treatment of PFAS-contaminated water using ion exchange resins and separation membranes - Deactivation of PFAS through hydrolysis, electrolysis, thermal decomposition, and incineration - Decomposition of PFAS using subcritical water treatment, atmospheric pressure plasma, cavitation, and bacteria - Insolubilization treatment of PFAS-contaminated soil and in-situ purification

  • IPROS3391385136135994447_220x220.png
  • others

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Technical Data: Bioseparation Handbook

A comprehensive explanation of various separation modes, their principles, characteristics, and more, covering a wide range from the basics to actual measurements.

This document is a technical material that explains liquid chromatography. Liquid chromatography has become an essential method for the separation and analysis of biological samples. This guide provides a comprehensive explanation of various separation modes of liquid chromatography, their principles, and features, ranging from the basics to actual measurements. [Contents (excerpt)] - Properties of proteins and nucleic acids - Separation methods for biopolymers - Liquid chromatographs used for measuring biopolymers - Size exclusion chromatography - Ion exchange chromatography *For more details, please refer to the PDF document or feel free to contact us.

  • others

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Technical Data: SEC (GPC/GFC) Data Collection

Publishing SEC (GPC/GFC) data of various synthetic polymers! Introducing GPC data for 112 actual samples!

This document is a collection of data on size exclusion chromatography (SEC, GPC, GFC). (The SEC of biomacromolecules such as proteins is explained in detail in the "Bioseparation Handbook.") 【Contents】 Types and characteristics of columns Solvents used in SEC and their properties *Data examples* Polyolefins, PPS Synthetic rubber Styrene-based resins Polyvinyl chloride and vinyl chloride copolymers Polycarbonate Polyvinyl acetate, polyvinyl alcohol Methacrylic resins Polyamides Polyethers Polyesters Phenolic resins Urea resins, melamine resins, cresol resins Epoxy resins Polyurethanes Fluorine-based resins Cellulose derivatives and cellulose Organosiloxane-based polymers Cyanoacrylate resins Polysulfone, polyethersulfone Polyimide Polylactic acid, polycaprolactone Water-soluble polymers and polysaccharides *For more details, please refer to the PDF document or feel free to contact us.*

  • Analytical Equipment and Devices

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

GPC 総合カタログ

信頼と安心の創出!SuperHZシリーズやSuperMultiporePWシリーズなどをご紹介

当カタログでは、様々な「GPC」をご紹介しております。 優れた安定性と再現性を実現した、高速GPC装置「HLC-8420GPC EcoSEC Elite」をはじめ、優れた操作性のGPCワークステーション「EcoSEC Elite-WS」、超高温領域でも高い安定性を実現する、高温GPC装置 「HLC-8321GPC/HT」などを豊富に掲載。 画像と共に掲載しており、導入検討の際に参考にしやすい一冊と なっております。ぜひ、ご一読ください。 【掲載内容(一部)】 ■高速GPC装置 HLC-8420GPC EcoSEC Elite ■GPCワークステーション EcoSEC Elite-WS ■高温GPC装置 HLC-8321GPC/HT ■GPCワークステーション 8321GPC-WS ■SECカラム ※詳しくはPDF資料をご覧いただくか、お気軽にお問い合わせ下さい。

  • Other physicochemical equipment

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Scalable purification of full capsid AAV by chromatography.

Introducing a scalable AAV purification process and a method for separating full capsids and empty capsids using anion exchange chromatography.

Adeno-associated virus (AAV) is widely used as a vector for gene therapy. While it is often purified using ultracentrifugation at the lab scale, this method becomes difficult to scale up. A scalable method for purification is chromatography; however, separating full capsids (hereafter referred to as "full") that contain the genome from empty capsids (hereafter referred to as "empty") that do not contain the genome and do not contribute to titer has been challenging. When using AAV as a vector for gene therapy, it is desirable to remove empty capsids as much as possible due to their impact on titer and issues related to immunogenicity. This application note introduces a scalable AAV purification process and presents a method for separating empty and full capsids using anion exchange chromatography across multiple serotypes.

  • others

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Equipped with PIC-80 (dual channel) auto sampler.

The warranty period is 5 years! We will introduce various components such as high-pressure transfer pumps, anion columns, and cation columns.

■Column Temperature Box and Constant Temperature Device ・With official patent certificate ■Thermal Conductivity Detector ・5-electrode conductivity cell ■High-Pressure Transfer Pump ・Pressure test: 42Mpa ■6-Port Sampling Valve ・Texture: Peak ■Flow Path Device ・Texture: Peak ■Anion Column ・Test items: F-, Cl-, NO2-, PO4^3-, Br-, SO4^2-, NO3-, ClO2-, BrO3-, ClO3- ■Anion Suppressor ・Automatic regeneration ■Cation Column ・Test items: Li+, Na+, NH4+, K+, Ca2+, Mg2+, Sr2+, Ba2+ ■Cation Suppressor ・Automatic regeneration ■IC Workstation ・Software ■Tools and Enclosures ・Spare parts and toolbox ■Auto Sampler ・Model PAS-III-DL-100, 100 units *For more details, please refer to the PDF document or feel free to contact us.*

  • Analytical Equipment and Devices

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

ACQUITY APC System

Next-generation GPC that achieves faster analysis while maintaining separation capability.

Japan Waters Corporation offers a next-generation ACQUITY APC system for polymer separation that enables extremely high-resolution size-based separations very quickly in the characterization analysis of polymers and oligomers using chromatography. 〇Features - Enables analysis that is 5 to 20 times faster than conventional GPC/SEC analysis conditions. - High resolution increases calibration points in the low molecular weight region, allowing for higher precision data acquisition from higher quality calibration curves. *For more details, please download the PDF or feel free to contact us.

  • Analytical Equipment and Devices

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

[Webinar Announcement] Membrane Chromatography That Does Not Require Resin Filling

No resin filling required. Introducing Sartobind Rapid A, ready to use immediately.

Improving the downstream process purification can reduce product costs, which has led to significant interest in enhancing the productivity of downstream processes. In this webinar, we will introduce the features of Sartobind Rapid A, which eliminates the need for affinity resin and achieves a reduction in process time. 【Seminar Overview】 ■ Date: November 21 (Thursday) from 3:00 PM (approximately 20 minutes) ■ Format: Webinar recorded broadcast [Japanese, Free] If you are unable to attend on the day, please register first. A viewing URL will be sent to you later. *We apologize, but participation from other companies in the same industry and email addresses not associated with your organization is not permitted. Thank you for your understanding.

  • Filtration Filter

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Related Categories of Chromatography equipment